Description
HAWK PT2 series pressure transmitters and transducers have been designed for measurement of viscous and contaminated fluids at high quality performance, reliability and cost.
The semi-flush front ceramic diaphragm design minimizes the dead space in order to avoid the highly viscous medium to clog the pressure sensing element. It’s good ideal for the system to require flushing to prevent contamination when changing pressure medium. The ceramic cell and metallic wetted parts can be compatible with majority of aggressive process fluids. Each transmitter is inspected and calibrated to ensure it’s 100% quality.
Typical Applications
- Pharmaceutical Industry
- Wastewater and Sewage Treatment
- Chemical Industries
- Tank Level Measurement
- Continuous Fluid Level Measurement
Specifications
PERFORMANCE
Accuracy at 25oC (Linearity, Hysteresis, Repeatability):
< ±0.25% F.S…..PT23.
< ±0.5% F.S…..PT24.
Stability at 25oC:
< ±0.2% F.S.(PT23).
< ±0.4% F.S.(PT24).
Thermal Zero Shift:
< ±0.02% F.S./ oC…..PT23.
< ±0.04% F.S./ oC…..PT24.
Thermal Span Shift:
< ±0.03% F.S./ oC.
ENVIRONMENTAL
Operating Temperature Range:
-25…..85 oC.
Storage Temperature Range:
-25…..100 oC.
Compensated Range:
-40…..135 oC.
Weatherproof Rating (Enclosure):
IP65, NEMA4/4X or better.
PHYSICAL DATA
Housing (Case):
304 Stainless Steel (316SS Option).
Fitting Materials:
304SS, 316SS, 316LSS, Monel or Hast’C.
Ceramic Sensor:
Aluminum Oxide Al2O3 (96%).
Seal Material:
FPM (Viton), NBR (Buna Rubber), MVQ (Silicone Rubber), CR (Neoprene), EPDM (Ethylene Propylene), FFKM.
Note: The wetted parts including fitting, ceramic sensor and sealing will be contacted with the media directly, please choose the appropriate material complied to your application.
Process Fitting (Connection):
G3/4 (3/4″PF), G1/2 (1/2″PF) – Standard, 1/2″ NPT, 3/4″ NPT, Others on request.
Electrical Connector:
Terminal Box to DIN43650 (IP 65),
Shutter Type Cable (IP 65),
Flexible Cable (IP 65),
Female 1/2″ DIN (IP 65),
M12 Cable (IP 65).
ELECTRICAL DATA
Voltage Output
Output Signal (Voltage, 3 Wires):
0-10V, 0-5V, 0.5-4.5V, 1-5V, 1-6V.
Power Requirement (Voltage):
15-32VDC (Normal 24VDC, Voltage).
Load Resistance (Voltage):
>10K Ohms.
Current Output
Output Signal (Current, 2 Wires):
4-20 mA.
Power Requirement (Current):
10-32VDC.(Normal 24VDC, Current).
Load Resistance (Current):
≦(Supply Voltage -10V) / (0.02A)Ohms.